TEMPERATURE MEASUREMENT |
|
Scale
Range: |
-40°C to 1100°C or -40°F to
2000°F |
|
Resolution: |
1.0°C or 1.0°F |
|
Accuracy: |
±1% of Reading, ±1.0° |
|
Repeatability: |
±1.0°C or ±2.0°F |
|
Temperature: |
All Functions in
°C or
°F |
|
Noise
Effective Temperature: |
<1.0°C
|
|
OPTICAL CONSIDERATIONS |
|
Optical
Configuration: |
Robust,
Aerospace-Quality, Double-Coated Zinc Selenide Optics per Military
Specification MIL-C-13508 |
|
Spectral
Pass Band: |
8 <
Wavelengths < 14 Microns |
|
Sighting: |
Line of
Sight |
|
Field of
View: |
Standard: 2° Optional: 15°
|
|
OPERATING CONDITIONS |
|
|
Operating
Environment: |
-40°C to
100°C or -40°F
to 212°F, up to 99% Relative Humidity, Non-Condensing |
|
Storage
Temperature: |
Same as
Operating Environment Temperature |
|
ELECTRICAL INTERFACE |
| Power
Requirements: |
5V to 26V
DC (Current Draw: 10 mA + Current Signal) |
|
Output Signal: |
Standard: Analog Millivolt (1.0mV/ °C)
Optional: 0-5 Volt, 4-20 mA and Type J or K Simulated Thermocouple |
|
GENERAL |
|
|
Response
Time: |
Standard: .05 Second;
Optional: .10 Second, 10% - 90% |
| Emissivity
Compensation: |
0.1 to 0.98 Settable |
|
Operating Distance: |
2 mm to 300 meters |
|
Dimensions: |
5/8" Diameter by 2-1/4" Length |
|
Warranty: |
One-Year Limited
Warranty on Parts & Labor |