TEMPERATURE MEASUREMENT
Scale Range: -40°C to 1100°C or -40°F to 2000°F
Resolution: 1.0°C or 1.0°F
Accuracy: ±1% of Reading, ±1.0°
Repeatability: ±1.0°C or  ±2.0°F
Temperature: All Functions in °C or °F, Corresponding to Voltage/Current Out
Noise Effective Temperature: <1.0°C
OPTICAL CONSIDERATIONS
Optical Configuration: Robust, Aerospace-Quality, Double-Coated Zinc Selenide Optics per Military Specification MIL-C-13508
Spectral Pass Band: 8 < Wavelengths < 14 Microns
Sighting: TTL/SLR Intra-Optical Light Sighting (Patent No. 4,494,881)
Focus: Focusable with VARIO-ZOOOM Sighting System (Patent No. 7,355,178)
OPERATING CONDITIONS  
Operating Environment: -40°C to 100°C or -40°F to 200°F, up to 95% Relative Humidity, Non-Condensing
Storage Temperature: Same as Operating Environment Temperature
ELECTRICAL INTERFACE
Power Requirements: 5V to 26V DC (Current Draw:  40 mA)
Output Signal: Standard:  4-20 mA, 0-5 Volts or 1.0 mV/°C Differentially
Optional:  Type J or K Thermocouple
GENERAL  
Response Time: .035 Second
Emissivity Compensation: 0.1 to 0.98 Settable
Operating Distance: 2 mm to 300 Meters
Dimensions: 3/4" Diameter by 2" Length
Warranty: One-Year Limited Warranty on Parts & Labor

Everest Interscience, Inc. has a policy of continued design upgrade. Therefore, we reserve the right to change specifications without notice.